Motor Testing
Soft Foot
In electric motors, soft foot distorts the frame, which in turn can distort the stator magnetic field...
The Challenges Faced Diagnosing Vertical Pump Defects
In this short video, we will review the history of Vertical Pumps and the types of Vertical Pumps. We'll also discuss the obstacles that are encountered in the field and provide some case history examples...
- Allen Bailey
- IVC Technologies
Vibration Measurement Techniques for Continuously Varying Speed Machinery
There are a lot of equipment types in industry that exhibit continuously varying speed. This presents a number of challenges to the vibration analyst. If a time sample is collected as the machine is continuously changing speed, the FFT will produce a virtually useless plot...
- Greg Lee
- PRUFTECHNIK
Combined Use of ESA, MCSA and Vibration for Accurate TTFE
In this presentation will will discuss the vibration and ESA fault detection of rotor bar faults in three medium voltage compressor motors and how the combined use allowed the risk of catastrophic failure to be assessed...
- Howard Penrose
- MotorDoc LLC
MCEmax Finds High Resistance Connection
Listen to Noah Bethel and Todd Gunderson as they explain how the MCEMax was used to identify a High Resistance Connection in one motor and an AirGap issue in another...
In-Rush/Start-Up Current Test Prevents Catastrophic Failure
The In-Rush/Start-up test was designed to look at the in-rush and decay of current during a direct start. In this case study, we evaluate the answer as it applies to a utility company...
- Noah Bethel
- PdMA Corporation
Energized Motor Testing Reveals Improper VFD Settings
This 55-kilowatt, 400-volt motor is controlled by a variable frequency drive (VFD). This motor drives the centrifugal fan that sends air into a natural gas combustion burner...
- Ettore Di Pasquale
- ALL-TEST PRO
What is 3 Minutes of Motor Testing Worth to You?
A motor distributor in the Netherlands provided a 17 Kilowatt, 400-Volt motor to a local hospital in 2015. The hospital rented a portable crane to install the motor onto the roof of the building. The motor is used to operate a fan that is mounted on the hospital’s roof...
- Richard Scott
- ALL-TEST PRO
Deep Well Vertical Pump Analysis using Electrical Signature Analysis (ESA)
There are many advantages that vertical pumps provide over horizontally mounted pumps and when they operate properly they generally provide many years of reliable, maintenance free operation. However, in almost any plant with a large inventory of vertical pumps they will have one or more of these pumps that are considered “bad actors”...
- 1
- …
- 17
- 18
- 19
- 20