Fmax, lines of resolution, averages, and units in the FFT analyzer. The video describes important settings in the vibration data collector and FFT vibration analyzer when signal processing to create the vibration spectrum
The FFT spectrum analyzer or digital data collector performs signal processing including filtering vibration signals. This short video gives an overview of low pass, high pass, band pass filters used in vibration analysis data collectors.
A 398 KW MV motor that runs a blower fan in a cement plant was showing strange behavior. The vibration equipment indicated vibration amplitudes that became chronic with the passage of time. The maintenance team, not knowing what the issue was, ran the motor until the bearings had to be replaced...
In May 2015, a K-3603 HHP BOG compressor tripped on high-high radial vibration, exceeding trip setting 83 μm peak to peak as the compressor discharge pressure increased to 68 bars.